Get a quote
Two linked green tanks beside a suburban house with a pump and pressure vessel in an open pump box and a row of valves on the wall at dusk

Backup water systems: keeping the house running when the mains stops

Taps that keep running. Free quotes from tank dealers, pump shops, plumbers, drillers and water carters across South Africa: one request, no obligation.

Installers and services. For homes during outages.

Backup water tank installation means the house carries on when the municipal water stops: the toilets flush, the kitchen tap runs and the shower has pressure. Whether the cause is pipeline work by the bulk water utility, a burst main or low pressure every evening, home backup water storage works only as a system. A tank on its own is a large bucket; with a pump, a bypass and the right valves, the switch over takes seconds.

Price guideA cost guide puts a simple 1,000 L backup tank at about R7,000 to R11,000 installed and an integrated 5,000 L system with a pump at about R20,000 to R35,000, or about R4 to R11 a litre of storageA rough guide from published South African prices. The area, the term, the grade, what is included and VAT all move it.

How the parts fit together

  1. The mains fills the tank through a float valve, so it is always full when the outage starts.
  2. A pump with a pressure vessel takes water from the tank and pushes it into the house.
  3. A bypass valve, manual or automatic, chooses mains or tank.
  4. A non-return valve stops tank water flowing back into the street main.

Ask whether the whole house is fed or only the toilets, the kitchen and one bathroom. Feeding only those circuits keeps the tank smaller and the water lasts longer.

Sizing for the days you need

Size for the length of outage your area usually has, not the tank on special. A household that uses 150 L a person a day, with four people and three days to cover, needs about 1,800 L, before the garden or the pool. Many Gauteng families went for two 2,500 L tanks after the long cuts of 2023 and 2024. Work it out with the water tank size calculator.

When the power goes off with the water

The pump needs electricity, and outages and load shedding often come together. The options are a battery backup sized for the pump's start up surge, a small solar setup, or a tank high enough to feed some taps by gravity through a separate line. A tank on a 2 m stand gives about 0.2 bar, enough to fill a cistern, not to run a shower. See water tank stands for the height question.

Stale water and the geyser

A tank that sits full for months can go flat and stale. Set the system up so household water runs through the tank every day, which keeps it turning over. A geyser on tank pressure works, but the pump must give at least the pressure the geyser was set for, or hot and cold mix badly at the shower.

Who asks for this

Homeowners and tenants
A tank, pump and bypass that keep the taps running through a three day outage.
Complexes, estates and landlords
A shared backup tank and pump room for a block of flats or a townhouse complex.
Builders and plumbers
Space, plinth and plumbing for a backup system planned into a new house.
Shops, restaurants and offices
A restaurant or practice that cannot close its doors each time the water is cut.
Farms, plots and lodges
A backup tank at the farmhouse when the borehole pump or the scheme pipeline fails.
Factories, mines and plants
Storage that keeps staff washrooms and canteens working while the mains is off.
Schools, clinics and municipalities
A clinic or school that needs water for hand washing and toilets during outages.
Events, sites and relief
A venue that keeps backup storage so a weekend booking survives a municipal cut.

Frequently asked questions

Is an automatic bypass worth it over a manual one?

An automatic valve changes over when the mains pressure drops, which suits people away at work. A manual valve is cheaper and simple, but someone must be home to turn it. Both need a plumber to fit.

What size water tank and pump do I need for a backup?

Size the tank in days and the pump by how many taps run at once. Two people showering while the washing machine fills is a typical peak for a family; ask the installer to size for that.

Do I need permission for a backup water system?

The connection to the house plumbing needs a registered plumber and a certificate, and many municipalities ask for tanks connected to the supply to be registered. Check with your municipality.

Who will quote on a backup system?

Plumbers, tank dealers and pump shops near you that install complete systems. We pass on your request; we install nothing ourselves.

Work it out first

More water storage topics

Get a quote for backup water systems

Fill in the docket: what you need, how many litres or how big, where it must go, and by when. Tank dealers, pump shops, plumbers, drillers and water carters in your area quote you directly. It is free and there is no obligation.

Delivery docket forBackup Water Systems
Docket
WS-9258
Status
Not sent

The request

How much water optional, it helps the quote

25 L is the bare minimum, 50 L careful use, 150 L normal use.

Storage linerule of thumb

-

-
-
-
-
-
-
Estimate
on quote

A rule of thumb for the request, not a quote.

Where and when

The list optional

Up to 12 lines: tanks, stands, pumps, filters, fittings, gutters.

Usual lines, tap to add:

Needs and options

You

Free and no obligation. By sending you agree that we may share your request with suitable suppliers, installers, plumbers, drillers and water carters. See our privacy policy.